Med. intensiva (Madr., Ed. impr.) ; 48(1): 3-13, Ene. 2024.
Artigo em Inglês | IBECS | ID: ibc-228948

RESUMO

Objective To determine if potential predictors for invasive mechanical ventilation (IMV) are also determinants for mortality in COVID-19-associated acute respiratory distress syndrome (C-ARDS). Design Single center highly detailed longitudinal observational study. Setting Tertiary hospital ICU: two first COVID-19 pandemic waves, Madrid, Spain. Patients or participants : 280 patients with C-ARDS, not requiring IMV on admission. Interventions None. Main variables of interest : Target: endotracheal intubation and IMV, mortality. Predictors: demographics, hourly evolution of oxygenation, clinical data, and laboratory results. Results The time between symptom onset and ICU admission, the APACHE II score, the ROX index, and procalcitonin levels in blood were potential predictors related to both IMV and mortality. The ROX index was the most significant predictor associated with IMV, while APACHE II, LDH, and DaysSympICU were the most with mortality. Conclusions According to the results of the analysis, there are significant predictors linked with IMV and mortality in C-ARDS patients, including the time between symptom onset and ICU admission, the severity of the COVID-19 waves, and several clinical and laboratory measures. These findings may help clinicians to better identify patients at risk for IMV and mortality and improve their management. (AU)


Objetivo Determinar si las variables clínicas independientes que condicionan el inicio de ventilación mecánica invasiva (VMI) son los mismos que condicionan la mortalidad en el síndrome de distrés respiratorio agudo asociado con COVID-19 (C-SDRA). Diseño Estudio observacional longitudinal en un solo centro. Ámbito UCI, hospital terciario: primeras dos olas de COVID-19 en Madrid, España. Pacientes o participantes 280 pacientes con C-SDRA que no requieren VMI al ingreso en UCI. Intervenciones Ninguna. Principales variables de interés Objetivo: VMI y Mortalidad. Predictores: demográficos, variables clínicas, resultados de laboratorio y evolución de la oxigenación. Resultados El tiempo entre el inicio de los síntomas y el ingreso en la UCI, la puntuación APACHE II, el índice ROX y los niveles de procalcitonina en sangre eran posibles predictores relacionados tanto con la IMV como con la mortalidad. El índice ROX fue el predictor más significativo asociada con la IMV, mientras que APACHE II, LDH y DaysSympICU fueron los más influyentes en la mortalidad. Conclusiones Según los resultados obtenidos se identifican predictores significativos vinculados con la VMI y mortalidad en pacientes con C-ARDS, incluido el tiempo entre el inicio de los síntomas y el ingreso en la UCI, la gravedad de las olas de COVID-19 y varias medidas clínicas y de laboratorio. Estos hallazgos pueden ayudar a los médicos a identificar mejor a los pacientes en riesgo de IMV y mortalidad y mejorar su manejo. (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Previsões/métodos , Respiração Artificial/efeitos adversos , /mortalidade , Inteligência Artificial/tendências , Aprendizado de Máquina/tendências , Pneumonia/complicações , Pneumonia/mortalidade , Estudos Longitudinais
2.
Med Intensiva (Engl Ed) ; 48(1): 3-13, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37500305

RESUMO

OBJECTIVE: To determine if potential predictors for invasive mechanical ventilation (IMV) are also determinants for mortality in COVID-19-associated acute respiratory distress syndrome (C-ARDS). DESIGN: Single center highly detailed longitudinal observational study. SETTING: Tertiary hospital ICU: two first COVID-19 pandemic waves, Madrid, Spain. PATIENTS OR PARTICIPANTS: 280 patients with C-ARDS, not requiring IMV on admission. INTERVENTIONS: None. MAIN VARIABLES OF INTEREST: Target: endotracheal intubation and IMV, mortality. PREDICTORS: demographics, hourly evolution of oxygenation, clinical data, and laboratory results. RESULTS: The time between symptom onset and ICU admission, the APACHE II score, the ROX index, and procalcitonin levels in blood were potential predictors related to both IMV and mortality. The ROX index was the most significant predictor associated with IMV, while APACHE II, LDH, and DaysSympICU were the most with mortality. CONCLUSIONS: According to the results of the analysis, there are significant predictors linked with IMV and mortality in C-ARDS patients, including the time between symptom onset and ICU admission, the severity of the COVID-19 waves, and several clinical and laboratory measures. These findings may help clinicians to better identify patients at risk for IMV and mortality and improve their management.


Assuntos
COVID-19 , Pneumonia , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial , COVID-19/terapia , Estado Terminal , Pandemias
3.
Sleep Breath ; 26(1): 361-371, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33792886

RESUMO

BACKGROUND: Alzheimer's disease (AD) causes symptoms such as dementia, memory loss, disorientation, and even aggressiveness, and is more common in women than in men. AD may also manifest itself in changes in sleep patterns. However, the relationship between AD (in all stages) and bedtime behavior has not been thoroughly investigated. METHODS: In a prospective, cross-sectional survey, we evaluated 74 women categorized in two different stages of cognitive decline associated with AD (mild and severe) along with 37 women with no cognitive decline who served as controls. We obtained demographic and medical information such as age, health status, and medication, as well as psychiatrically confirmed staging of AD. We also collected actigraphy data for several nights in a row with a medical grade wristband using a 3-axis accelerometer and solid-state on-board memory. These data served as parameters for a clustering machine learning (ML) algorithm. RESULTS: The ML process was able to unsupervisedly identify 85% of the participants according to their pre-assigned degree of dementia. When the clustering was carried out in a binary fashion (i.e., only taking into account healthy members vs. severely affected AD patients), it was possible to correctly classify 91% of the cases. CONCLUSIONS: This study revealed a strong connection between the severity of the intellectual decline and the features distilled from actigraphically derived sleep parameters.


Assuntos
Doença de Alzheimer/complicações , Disfunção Cognitiva/etiologia , Sono , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/fisiopatologia , Estudos Transversais , Feminino , Humanos , Estudos Prospectivos
4.
Sensors (Basel) ; 19(17)2019 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-31450624

RESUMO

Physics is considered a tough academic subject by learners. To leverage engagement in the learning of this STEM area, teachers try to come up with creative ideas about the design of their classroom lessons. Sports-related activities can foster intuitive knowledge about physics (gravity, speed, acceleration, etc.). In this context, martial arts also provide a novel way of visualizing these ideas when performing the predefined motions needed to master the associated techniques. The recent availability of cheap monitoring hardware (accelerometers, cameras, etc.) allows an easy tracking of the aforementioned movements, which in the case of aikido, usually involve genuine circular motions. In this paper, we begin by reporting a user study among high-school students showing that the physics concept of moment of inertia can be understood by watching live exhibitions of specific aikido techniques. Based on these findings, we later present Phy + Aik, a tool for educators that enables the production of innovative visual educational material consisting of high-quality videos (and live demonstrations) synchronized/tagged with the inertial data collected by sensors and visual tracking devices. We think that a similar approach, where sensors are automatically registered within an intelligent framework, can be explored to teach other difficult-to-learn STEM concepts.

5.
Med Phys ; 44(4): 1369-1378, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28160525

RESUMO

PURPOSE: Initial auto-adjustment of the window level WL and width WW applied to mammographic images. The proposed intensity windowing (IW) method is based on the maximization of the mutual information (MI) between a perceptual decomposition of the original 12-bit sources and their screen displayed 8-bit version. Besides zoom, color inversion and panning operations, IW is the most commonly performed task in daily screening and has a direct impact on diagnosis and the time involved in the process. METHODS: The authors present a human visual system and perception-based algorithm named GRAIL (Gabor-relying adjustment of image levels). GRAIL initially measures a mammogram's quality based on the MI between the original instance and its Gabor-filtered derivations. From this point on, the algorithm performs an automatic intensity windowing process that outputs the WL/WW that best displays each mammogram for screening. GRAIL starts with the default, high contrast, wide dynamic range 12-bit data, and then maximizes the graphical information presented in ordinary 8-bit displays. Tests have been carried out with several mammogram databases. They comprise correlations and an ANOVA analysis with the manual IW levels established by a group of radiologists. A complete MATLAB implementation of GRAIL is available at https://github.com/TheAnswerIsFortyTwo/GRAIL. RESULTS: Auto-leveled images show superior quality both perceptually and objectively compared to their full intensity range and compared to the application of other common methods like global contrast stretching (GCS). The correlations between the human determined intensity values and the ones estimated by our method surpass that of GCS. The ANOVA analysis with the upper intensity thresholds also reveals a similar outcome. GRAIL has also proven to specially perform better with images that contain micro-calcifications and/or foreign X-ray-opaque elements and with healthy BI-RADS A-type mammograms. It can also speed up the initial screening time by a mean of 4.5 s per image. CONCLUSIONS: A novel methodology is introduced that enables a quality-driven balancing of the WL/WW of mammographic images. This correction seeks the representation that maximizes the amount of graphical information contained in each image. The presented technique can contribute to the diagnosis and the overall efficiency of the breast screening session by suggesting, at the beginning, an optimal and customized windowing setting for each mammogram.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Automação , Mamografia
6.
Med Eng Phys ; 42: 73-79, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28223012

RESUMO

A method for deriving 3D internal information in conventional X-ray settings is presented. It is based on the combination of a pair of radiographs from a patient and it avoids the use of X-ray-opaque fiducials and external reference structures. To achieve this goal, we augment an ordinary X-ray device with a consumer RGB-D camera. The patient' s rotation around the craniocaudal axis is tracked relative to this camera thanks to the depth information provided and the application of a modern surface-mapping algorithm. The measured spatial information is then translated to the reference frame of the X-ray imaging system. By using the intrinsic parameters of the diagnostic equipment, epipolar geometry, and X-ray images of the patient at different angles, 3D internal positions can be obtained. Both the RGB-D and X-ray instruments are first geometrically calibrated to find their joint spatial transformation. The proposed method is applied to three rotating phantoms. The first two consist of an anthropomorphic head and a torso, which are filled with spherical lead bearings at precise locations. The third one is made of simple foam and has metal needles of several known lengths embedded in it. The results show that it is possible to resolve anatomical positions and lengths with a millimetric level of precision. With the proposed approach, internal 3D reconstructed coordinates and distances can be provided to the physician. It also contributes to reducing the invasiveness of ordinary X-ray environments and can replace other types of clinical explorations that are mainly aimed at measuring or geometrically relating elements that are present inside the patient's body.


Assuntos
Imageamento Tridimensional/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Imagens de Fantasmas
7.
Radiol Phys Technol ; 10(1): 68-81, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27431651

RESUMO

We explore three different alternatives for obtaining intrinsic and extrinsic parameters in conventional diagnostic X-ray frameworks: the direct linear transform (DLT), the Zhang method, and the Tsai approach. We analyze and describe the computational, operational, and mathematical background differences for these algorithms when they are applied to ordinary radiograph acquisition. For our study, we developed an initial 3D calibration frame with tin cross-shaped fiducials at specific locations. The three studied methods enable the derivation of projection matrices from 3D to 2D point correlations. We propose a set of metrics to compare the efficiency of each technique. One of these metrics consists of the calculation of the detector pixel density, which can be also included as part of the quality control sequence in general X-ray settings. The results show a clear superiority of the DLT approach, both in accuracy and operational suitability. We paid special attention to the Zhang calibration method. Although this technique has been extensively implemented in the field of computer vision, it has rarely been tested in depth in common radiograph production scenarios. Zhang's approach can operate on much simpler and more affordable 2D calibration frames, which were also tested in our research. We experimentally confirm that even three or four plane-image correspondences achieve accurate focal lengths.


Assuntos
Radiografia/métodos , Algoritmos , Calibragem , Radiografia/instrumentação
8.
IEEE Trans Med Imaging ; 35(8): 1952-61, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26978665

RESUMO

We present a methodology to recover the geometrical calibration of conventional X-ray settings with the help of an ordinary video camera and visible fiducials that are present in the scene. After calibration, equivalent points of interest can be easily identifiable with the help of the epipolar geometry. The same procedure also allows the measurement of real anatomic lengths and angles and obtains accurate 3D locations from image points. Our approach completely eliminates the need for X-ray-opaque reference marks (and necessary supporting frames) which can sometimes be invasive for the patient, occlude the radiographic picture, and end up projected outside the imaging sensor area in oblique protocols. Two possible frameworks are envisioned: a spatially shifting X-ray anode around the patient/object and a moving patient that moves/rotates while the imaging system remains fixed. As a proof of concept, experiences with a device under test (DUT), an anthropomorphic phantom and a real brachytherapy session have been carried out. The results show that it is possible to identify common points with a proper level of accuracy and retrieve three-dimensional locations, lengths and shapes with a millimetric level of precision. The presented approach is simple and compatible with both current and legacy widespread diagnostic X-ray imaging deployments and it can represent a good and inexpensive alternative to other radiological modalities like CT.


Assuntos
Imageamento Tridimensional , Calibragem , Imagens de Fantasmas , Raios X
SELEÇÃO DE REFERÊNCIAS